Administration Status Change Alarm

acgwAdminStateChange

Alarm

acgwAdminStateChange

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.7

Description

The alarm is sent when Graceful Shutdown commences and ends.

Default Severity

Major

Event Type

processingErrorAlarm

Probable Cause

outOfService (71)

Severity

Condition

Text

Corrective Action

Major

Admin state changed to shutting down

"Network element admin state change alarm: Gateway is shutting down.  No time limit."

No corrective action is required.
A network administrator took an action to gracefully lock the device.

Major

Admin state changed to locked

"Locked"

No corrective action is required.
A network administrator took an action to lock the device, or a graceful lock timeout occurred.

Cleared

Admin state changed to unlocked

-

No corrective action is required.
A network administrator has taken an action to unlock the device.